Axis adjustment of C-mount mounted optics such as machine vision
・Issues
When there is a C-mount for measuring objects or optical axis adjustment, such as microscopes or inspection tubes, using a dedicated adapter will cause variations due to individual differences and
component tolerances.Is there any way to reduce the variation?
・Solutions
Using a tilt sensor with the measurement laser emitted perpendicularly and centrally to the flange surface of the C-mount, it is possible to align the lens optical axis with the measurement surface. It is also
possible to adjust the optical axis of inspection and measurement devices equipped with cameras, and to align them with the surface on which the measurement object is mounted. In addition, it is possible to
align the flange surface of the objective lens of microscope optical systems with the measurement surface on which the measurement object is mounted. This leads to shorter setup time and improved yield rate.